WEBVTT

1
00:00:02.350 --> 00:00:12.850
This joined sensor starts with a ten-minute report interval; Class A downlinks need a receive window after an uplink.

2
00:00:14.900 --> 00:00:24.400
For this sensor profile, choose port two and enter the supported command for a two-minute report interval.

3
00:00:26.600 --> 00:00:38.100
Submitting the request stores it on the server; the sensor keeps its current interval until the command is delivered and applied.

4
00:00:47.950 --> 00:00:56.950
Send a test uplink, then check the downlink events and read back the new two-minute interval.

5
00:01:01.750 --> 00:01:09.750
Disable only the gateway-to-sensor radio path; uplinks can still reach the server and application.

6
00:01:21.500 --> 00:01:31.850
Queue a three-minute command and send another uplink; application delivery continues, but the downlink misses its receive window.

7
00:01:33.600 --> 00:01:43.600
The unchanged interval confirms the command was not applied, so uplink success alone does not prove downlink delivery.

8
00:01:59.000 --> 00:02:09.000
Restore the radio path, queue a fresh command and send a new uplink to verify the three-minute interval.

9
00:02:10.900 --> 00:02:18.400
Reload the page and confirm the applied interval and both saved radio directions.