Use simulated environmental sensors to see how a higher workload changes temperature and fan speed.

00:00:19.150 --> 00:00:28.650
Select the router, open Edit device, and set the starting CPU load to fifty percent under Environmental.

00:00:35.100 --> 00:00:43.100
The temperature curve sets how much warmer the CPU runs above the inlet temperature.

00:00:45.900 --> 00:00:52.900
The fan curve sets how fast the fan spins at each temperature.

00:00:54.750 --> 00:01:01.750
Save the curves to activate the simulation and note the starting readings.

00:01:07.900 --> 00:01:15.900
Run show environment in the CLI to check the same temperature and fan speed.

00:01:23.050 --> 00:01:30.550
Open SNMP Walk and read the sensor values from the Entity Sensor MIB.

00:01:39.800 --> 00:01:48.800
Next to SNMP Walk, open the gNMI Browser and use Get to read the CPU temperature.

00:01:52.050 --> 00:01:58.050
Read the fan speed from the same OpenConfig component tree.

00:02:07.250 --> 00:02:14.250
Raise the CPU load to ninety percent, then save the curves again.

00:02:20.100 --> 00:02:27.100
Run show environment again to confirm the router reports the higher readings.

00:02:34.350 --> 00:02:41.850
Repeat the SNMP walk to see the same change in the sensor table.

00:02:50.700 --> 00:02:55.800
Run another gNMI Get for the updated temperature.

00:02:59.050 --> 00:03:05.550
Query the fan again to confirm its speed has increased too.

00:03:11.350 --> 00:03:19.350
Reopen Environmental to confirm that the new load and its sensor readings were saved.