Simulate device temperature and fan speed Use simulated environmental sensors to see how a higher workload changes temperature and fan speed. Select the router, open Edit device, and set the starting CPU load to fifty percent under Environmental. The temperature curve sets how much warmer the CPU runs above the inlet temperature. The fan curve sets how fast the fan spins at each temperature. Save the curves to activate the simulation and note the starting readings. Run show environment in the CLI to check the same temperature and fan speed. Open SNMP Walk and read the sensor values from the Entity Sensor MIB. Next to SNMP Walk, open the gNMI Browser and use Get to read the CPU temperature. Read the fan speed from the same OpenConfig component tree. Raise the CPU load to ninety percent, then save the curves again. Run show environment again to confirm the router reports the higher readings. Repeat the SNMP walk to see the same change in the sensor table. Run another gNMI Get for the updated temperature. Query the fan again to confirm its speed has increased too. Reopen Environmental to confirm that the new load and its sensor readings were saved.