IoT · Episode 08 · 2:18

Queue LoRaWAN downlinks and recover a radio path

Queue a LoRaWAN report-interval command, verify that it reaches and changes the sensor, then diagnose a failed return radio path while uplinks continue. Restore the path and verify a fresh command.

English narration and on-screen explanations. Read the narration transcript.

Chapters and transcript times will be ready shortly. You can use the video’s Play control or open the MP4 below.

Chapters
Open MP4 · Download transcript · English captions

Narration transcript

The English narration in this video. Select a time to watch that moment.

  1. This joined sensor starts with a ten-minute report interval; Class A downlinks need a receive window after an uplink.

  2. For this sensor profile, choose port two and enter the supported command for a two-minute report interval.

  3. Submitting the request stores it on the server; the sensor keeps its current interval until the command is delivered and applied.

  4. Send a test uplink, then check the downlink events and read back the new two-minute interval.

  5. Disable only the gateway-to-sensor radio path; uplinks can still reach the server and application.

  6. Queue a three-minute command and send another uplink; application delivery continues, but the downlink misses its receive window.

  7. The unchanged interval confirms the command was not applied, so uplink success alone does not prove downlink delivery.

  8. Restore the radio path, queue a fresh command and send a new uplink to verify the three-minute interval.

  9. Reload the page and confirm the applied interval and both saved radio directions.